Coombs test

From Infogalactic: the planetary knowledge core
Jump to: navigation, search
Coombs test
Diagnostics
MeSH D003298
MedlinePlus 003344
[[[d:Lua error in Module:Wikidata at line 863: attempt to index field 'wikibase' (a nil value).|edit on Wikidata]]]

A Coombs test (also known as Coombs' test, antiglobulin test or AGT) is either of two clinical blood tests used in immunohematology and immunology. The two Coombs tests are the direct Coombs test (DCT, also known as direct antiglobulin test or DAT), and the indirect Coombs test (also known as indirect antiglobulin test or IAT).

The direct Coombs test is used to test for autoimmune hemolytic anemia; i.e., a condition of a low count of red blood cells (aka RBCs) caused by immune system lysis or breaking of RBC membranes causing RBC destruction.

In certain diseases or conditions, an individual's blood may contain IgG antibodies that can specifically bind to antigens on the RBC surface membrane, and their circulating RBCs can become coated with IgG alloantibodies and/or IgG autoantibodies. Complement proteins may subsequently bind to the bound antibodies and cause RBC destruction.[1] The direct Coombs test is used to detect these antibodies or complement proteins that are bound to the surface of red blood cells; a blood sample is taken and the RBCs are washed (removing the patient's own plasma) and then incubated with anti-human globulin (also known as "Coombs reagent"). If this produces agglutination of RBCs, the direct Coombs test is positive, a visual indication that antibodies (and/or complement proteins) are bound to the surface of red blood cells.

The indirect Coombs test is used in prenatal testing of pregnant women and in testing blood prior to a blood transfusion. It detects antibodies against RBCs that are present unbound in the patient's serum. In this case, serum is extracted from the blood sample taken from the patient. Then, the serum is incubated with RBCs of known antigenicity; that is, RBCs with known reference values from other patient blood samples. If agglutination occurs, the indirect Coombs test is positive.[2]

Mechanism

Schematic showing the direct and indirect Coombs tests.

The two Coombs tests are based on the fact that anti-human antibodies, which are produced by immunizing non-human species with human serum, will bind to human antibodies, commonly IgG or IgM. Animal anti-human antibodies will also bind to human antibodies that may be fixed onto antigens on the surface of red blood cells (also referred to as RBCs), and in the appropriate test tube conditions this can lead to agglutination of RBCs. The phenomenon of agglutination of RBCs is important here, because the resulting clumping of RBCs can be visualised; when clumping is seen the test is positive and when clumping is not seen the test is negative.

Common clinical uses of the Coombs test include the preparation of blood for transfusion in cross-matching, atypical antibodies in the blood plasma of pregnant women as part of antenatal care, and detection of antibodies for the diagnosis of immune-mediated haemolytic anemias.

Coombs tests are done on serum from venous blood samples which are taken from patients by venipuncture. The venous blood is taken to a laboratory (or blood bank), where trained scientific technical staff do the Coombs tests. The clinical significance of the result is assessed by the physician who requested the Coombs test, perhaps with assistance from a laboratory-based hematologist.

Direct Coombs test

The direct Coombs test (also known as the direct antiglobulin test or DAT) is used to detect if antibodies or complement system factors have bound to RBCs surface antigens in vivo. The DAT is not currently required for pre-transfusion testing but may be included by some laboratories.[medical citation needed][clarification needed]

Examples of diseases that give a positive direct Coombs test

The direct Coombs test is used clinically when immune-mediated hemolytic anemia (antibody-mediated destruction of RBCs) is suspected. A positive Coombs test indicates that an immune mechanism is attacking the patient's own RBCs. This mechanism could be autoimmunity, alloimmunity or a drug-induced immune-mediated mechanism.

Examples of alloimmune hemolysis

Examples of autoimmune hemolysis/immunohemolytic hemolysis

Drug-induced immune-mediated hemolysis

  • Methyldopa (IgG mediated type II hypersensitivity)
  • Penicillin (high dose)
  • Quinidine (IgM mediated activation of classical complement pathway and Membrane attack complex, MAC)

(A memory device to remember that the DAT tests the RBCs and is used to test infants for haemolytic disease of the newborn is: Rh Disease; R = RBCs, D = DAT.)

Laboratory method

The patient's RBCs are washed (removing the patient's own serum) and then centrifuged with antihuman globulin (also known as Coombs reagent). If immunoglobulin or complement factors have been fixed on to the RBC surface in-vivo, the antihuman globulin will agglutinate the RBCs and the direct Coombs test will be positive. (A visual representation of a positive direct Coombs test is shown in the upper half of the schematic).

Indirect Coombs test

The indirect Coombs test (also known as the indirect antiglobulin test or IAT) is used to detect in-vitro antibody-antigen reactions. It is used to detect very low concentrations of antibodies present in a patient's plasma/serum prior to a blood transfusion. In antenatal care, the IAT is used to screen pregnant women for antibodies that may cause hemolytic disease of the newborn. The IAT can also be used for compatibility testing, antibody identification, RBC phenotyping, and titration studies.

Examples of clinical uses of the indirect Coombs test

Blood transfusion preparation

<templatestyles src="Module:Hatnote/styles.css"></templatestyles>

The indirect Coombs test is used to screen for antibodies in the preparation of blood for blood transfusion. The donor's and recipient's blood must be ABO and Rh D compatible. Donor blood for transfusion is also screened for infections in separate processes.

  • Antibody screening

A blood sample from the recipient and a blood sample from every unit of donor blood are screened for antibodies with the indirect Coombs test. Each sample is incubated against a wide range of RBCs that together exhibit a full range of surface antigens (i.e. blood types).

  • Cross matching

The indirect Coombs test is used to test a sample of the recipient's serum for antibodies against a sample of the blood donor's RBCs. This is sometimes called cross-matching blood.

Antenatal antibody screening

The indirect Coombs test is used to screen pregnant women for IgG antibodies that are likely to pass through the placenta into the fetal blood and cause haemolytic disease of the newborn.

Laboratory method

The IAT is a two-stage test. (A cross match is shown visually in the lower half of the schematic as an example of an indirect Coombs test).

First stage

Washed test red blood cells (RBCs) are incubated with a known human serum. If the serum contains antibodies to antigens on the RBC surface, the antibodies will bind onto the surface of the RBCs.

Second stage

The RBCs are washed three or four times with isotonic saline and then incubated with antihuman globulin. If antibodies have bound to RBC surface antigens in the first stage, RBCs will agglutinate when incubated with the antihuman globulin (also known Coombs reagent) in this stage, and the indirect Coombs test will be positive.

Titrations

By diluting a serum containing antibodies the quantity of the antibody in the serum can be gauged. This is done by using doubling dilutions of the serum and finding the maximum dilution of test serum that is able to produce agglutination of relevant RBCs.

Coombs reagent

Coombs reagent (also known as Coombs antiglobulin or antihuman globulin) is used in both the direct Coombs test and the indirect Coombs test. Coombs reagent is antihuman globulin. It is made by injecting human globulin into animals, which produce polyclonal antibodies specific for human immunoglobulins and human complement system factors. More specific Coombs reagents or monoclonal antibodies can be used.

Enhancement media

Both IgM and IgG antibodies bind strongly with their antigens. IgG antibodies are most reactive at 37 °C. IgM antibodies are easily detected in saline at room temperature as IgM antibodies are able to bridge between RBC’s owing to their large size, efficiently creating what is seen as agglutination. IgG antibodies are smaller and require assistance to bridge well enough to form a visual agglutination reaction. Reagents used to enhance IgG detection are referred to as potentiators. RBCs have a net negative charge called zeta potential which causes them to have a natural repulsion for one another. Potentiators reduce the zeta potential of RBC membranes. Common potentiators include low ionic strength solution (LISS), albumin, polyethylene glycol (PEG), and proteolytic enzymes.

History of the Coombs test

The Coombs test was first described in 1945 by Cambridge immunologists Robin Coombs (after whom it is named), Arthur Mourant and Rob Race.[3] Historically, it was done in test tubes. Today, it is commonly done using microarray and gel technology.

References

  1. Hemolytic anemia
  2. F. Rosen and R. Geha, Case Studies in Immunology, 4th ed., Garland Science, p.173.
  3. Coombs RRA, Mourant AE, Race RR. A new test for the detection of weak and "incomplete" Rh agglutinins. Brit J Exp Path 1945;26:255-66.

External links