Pulse-frequency modulation
Pulse-Frequency Modulation (PFM) is a modulation method for representing an analog signal using only two levels (1 and 0). It is analogous to Pulse-Width Modulation (PWM), in which the magnitude of an analog signal is encoded in the duty cycle of a square wave. Unlike PWM, in which the width of square pulses is varied at constant frequency, PFM fixes the width of square pulses while varying the frequency. In other words, the frequency of the pulse train is varied in accordance with the instantaneous amplitude of the modulating signal at sampling intervals. The amplitude and width of the pulses is kept constant.
Applications
PFM is a method of encoding analog signals into trains of square pulses, and therefore has a wide variety of applications. There are practical difficulties in the design of electronics when working with non fixed frequencies, such as transmission line effects in board layout and magnetic component selection, so generally PWM mode is preferred. There are, however, select cases in which PFM mode is preferred.
Buck Converters
PFM mode is a common technique for increasing the efficiency of switching step down DC-DC converters (Buck Converters) when driving light loads.
In medium to high loads, the DC resistance of buck converter switching elements tends to dominate the overall efficiency of the Buck Converter. When driving light loads, however, the effects of DC resistances are reduced and AC losses in the inductor, capacitor, and switching elements play a larger role in overall efficiency. This is especially true in discontinuous mode operation, in which the inductor current drops below zero, resulting in the discharging of the output capacitor and even higher switching losses.
PFM mode operation allows the switching frequency to be reduced and for a control method that prevent the inductor current from dropping below zero, therefore greatly reducing the impact of switching losses. Rather than applying square pulses of varying widths to the inductor, square pulse trains with a fixed 50% duty cycle are used to charge the inductor to a predefined current limit the discharge it to a current at, but not below, 0. In between the square pulse trains, the inductor current is allowed to fall to zero, giving a long "dead zone". The frequency of these pulse trains is then varied to maintain the desired output voltage with the aid of the output filter capacitor. [1]
By fixing the duty cycle of the pulse trains to 50%, the switching losses of the buck converter switching elements are reduced. In addition, the inductor is given known levels of peak current, which if chosen carefully in regards to saturation current can reduce switching losses in its magnetic core.
This is all done at the expense of output voltage and current ripple, which increases as a result of the reduction in switching frequency.
External links
See also
- Pulse-Width Modulation
- Pulse-amplitude modulation
- Pulse-code modulation
- Pulse-density modulation
- Pulse-position modulation
- Rate coding, pulse-frequency modulation in living systems
References
<templatestyles src="Reflist/styles.css" />
Cite error: Invalid <references>
tag; parameter "group" is allowed only.
<references />
, or <references group="..." />
Lenk, John D. (1999). "Circuit Troubleshooting Handbook" p242. McGraw-Hill, New York
<templatestyles src="Asbox/styles.css"></templatestyles>
ta:துடிப்பு அதிர்வெண் குறிப்பேற்றம்
- ↑ Lua error in package.lua at line 80: module 'strict' not found.